6.3 Initializing the Settings of this Product

The following two cases are available for initializing the setting of this product.
① Initializes the camera back to the user setting (ENGINEER SET FILE).
This initializes the camera back to the state set by user engineer in advance in response to the environment and the shooting
conditions.
② Initializes the camera back to the initial factory setting (FACTORY SET FILE)
This initializes the camera back to the initial factory setting.
To change the settings, select "PRESET FILE LOAD" on MENU (3/4), then "FILE SELECT" and "LOAD START".
The following explains the set values, descriptions, and setting procedures.
Set Value
FILE SELECT
ENGINEER (default)
FACTORY
LOAD START
READY (default)
START
CANCEL
1
On MENU (3/4), turn the MENU SELECT switch to
position the cursor on "PRESET FILE LOAD", and
press the MENU SELECT switch.
The submenu is displayed.
2
Turn the MENU SELECT switch to position the
cursor on "FILE SELECT", and press the MENU
SELECT switch.
The cursor moves to the mode selection column.
3
Turn the MENU SELECT switch to select the value
to be set, and press the MENU SELECT switch.
The value is con rmed.
4
Press the MENU SELECT switch when the cursor
automatically moves to "LOAD START".
The cursor moves to the mode selection column and its
display changes from "READY" to "START".
Initializes the state back to the user setting.
Initializes the state back to the initial factory setting.
The state before initialization
Starts initialization.
Cancels initialization.
*** MENU (3/4) ***
SCAN FORMAT SELECT
CPU SYSTEM CONTROL
AUTO IRIS SET
AUTO SETUP MODE
LENS SELECT
LEVEL ADJUST
PROCESS MODE
PRESET FILE LOAD
PRESET FILE LOAD
FILE SELECT    ENGINEER
LOAD START     READY
PRESET FILE LOAD
FILE SELECT    ENGINEER
LOAD START     READY
PRESET FILE LOAD
FILE SELECT    ENGINEER
LOAD START     READY
HDK-790GX 1403 VER1 (U)
6.3 Initializing the Settings of this Product
Description
Position the cursor on
"PRESET FILE LOAD"
and confirm.
Position the cursor on
"FILE SELECT" and
confirm.
Select "ENGINEER"
or "FACTORY" and
confirm.
Position the cursor on
"LOAD START" and
confirm.
6