4.6 Auto Setup
FULL QUICK Auto Setup and QUICK Auto Setup
To activate the FULL QUICK auto setup or QUICK auto setup from the camera, select "F.QUICK" or "QUICK" from the camera
menu "AUTO SETUP MODE" - "AUTO SETUP". To perform the FULL QUICK/QUICK auto setup from an OCP or MCP,
perform the following steps.
1
Press the SETUP button in the function switch part.
2
Press the AUTO SETUP button on the LCD.
3
Press the Full Quick or Quick button on the LCD.
4
Press the Start button on the LCD.
Auto White Balance
The auto white balance is performed from the OCP or MCP. It cannot be performed from the camera.
1
Shoot the subject which contains white color.
Select the subject in which 10% or more of the screen area is occupied with white color when shooting.
2
Press the "AWB" button on the OCP or MCP.
The auto white balance will be performed.
3
Check the results.
"OK" or "NG" will be displayed on the view nder screen when completing the
auto white balance.
When "NG" is displayed, check if the subject satis es the above requirements
and the optical lter is correct. Then, repeat the procedure from step 1.
Caution:
Make sure that the R and B GAIN control knob of OCP or MCP is in the center position before performing the auto white balance. If
the control knob is not in the center position, the control range will be biased to one side.
60
HDK-790GX 1403 VER1 (U)
AWB Ach
O K