5.2 Settings from the Menu
- - -
MENU (2/4)
Menu Item
VIDEO OUTPUT MODE
| |
| |
― SDI OUT
|
| |
― MONITOR OUT
|
|
― MON SDI OUT
BARS MODE
| |
― BARS MODE
|
― BARS ON
FAN CONTROL
| |
| |
| |
― FAN CONT MODE
| |
| |
|
― FRONT BOTTOM
|
― BACKWARD BOTTOM
|
― POWER BOX
|
― VF CONT
|
― FAN CONDITION
|
― FRONT BOTTOM
|
― BACKWARD BOTTOM
|
― POWER BOX
H PHASE CONTROL
| |
|
― H PHASE
TIME SETTING
|
― TIME
|
― DATE(YY/MM/DD)
MEMORY CARD
|
| |
― SAVE FILE
― ALL DATA
| |
― SNAP SHOT
| |
― SCENE
| |
― REFERENCE
| |
― LENS
|
|
― MENU DATA
|
― LOAD FILE
|
― ALL DATA
|
― SNAP SHOT
| |
― SCENE
|
― REFERENCE
| |
― LENS
|
― MENU DATA
72
Initial
Setting value
setting
CAM
CAM, HD Q-TV
MON
MON, SYNC
VF, MAIN, RETURN,
VF
HD Q-TV
Destination
FULL, MULTI
setting
OFF
ON, OFF
AUTO, SLOW, QUIET,
AUTO
STOP
---
---
(information display)
---
---
---
---
(information display)
---
0.0
-100 to +100
---
HH : MM : SS
---
YY / MM / DD
---
---
---
---
---
---
---
---
---
ALL, SELECT NUMBER
---
---
ALL, SELECT NUMBER
---
ALL, VF
HDK-790GX 1403 VER1 (U)
Description, Remarks
Switches the signals (main line HDSDI) that are output
from the SDI-OUT connector.
CAM
: Outputs the main line signal.
HD Q-TV : Outputs the Q-TV signal of the HDTV that is sent
from the CCU/BS (if the CCU/BS is connected).
MON: Outputs the mono analog HD signal for the monitor.
SYNC: Outputs the tri-level sync signal.
Switches the signals (HD-SDI) output from the MON SDI
OUT connector.
VF
: Outputs same signals as VF images.
MAIN
: Outputs main line signals.
RETURN : Outputs RET signals.
FULL
: Displays the BARS signal conventionally used.
MULTI : Displays the multiformat BARS signal.
Turns the color bar signal ON/OFF.
AUTO : Automatically changes the cooling fan speed
according to the internal temperature level.
SLOW : Sets the fan to SSLOW for 5 minutes. After 5
minutes, the mode changes to AUTO.
QUIET : Stops the fan until the external temperature
becomes about 35 ℃ . Above that temperature the
fan is operated automatically.
STOP : Keeps the fan stopped as long as the internal
temperature does not reach a critical level. If the
power is turned on again, it returns to AUTO.
Displays the operation status of fan motor.
SSLOW : Operates at the lowest speed
SLOW : Operates at low speed
NOR
: Operates at normal speed
FAST
: Operates at high speed
OK : Normal
NG : Fan is stopped.
Adjusts the horizontal phase when using external synch.
Sets so that the phase of the internal SYNC signal matches
the phase of the external SYNC signal. The internal SYNC
advances in the direction of -100 in relation to the external
synch, and delays in the direction of +100.
Can only be set during self-operation.
Sets the time and date when saving the file to the memory
card.
Refer to "5.3 Using the Memory Card" for the memory
card usage method.
Saves the selected data to the memory card.
Loads all files.
Loads snapshot files.
Possible to select whether to load all from SCENE DATA or
to load individual data from 1 to 8.
Loads the reference file.
Possible to select whether to load all from LENS DATA or
to load individual data from 1 to 8.
Possible to select whether to load all menus from MENU
DATA or only those menus related to VF.
MENU DATA
ALL
VF
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-