Alarm Lamp On The Ocp Or Mcp Flashes On And Off - Ikegami HDK-790GX Operation Manual

High definition camera system
Table of Contents

Advertisement

Refer to this chapter when the alarm lamp lights or when you want to know about the maintenance during the use of this product.
- - -
Problems
- The alarm lamp on the OCP or on the MCP ashes ON and OFF.
- - -
- "TEMP!!" or "FAN!!" appears on the view nder screen.
Questions
- - -
- How to reset the settings to default (Return to the factory settings)
Maintenance
- Cleaning the camera connectors
- Resetting the breaker

6.1 Alarm Lamp on the OCP or MCP Flashes ON and OFF

The CCU is equipped with a self diagnostic function which monitors whether the CCU and camera are running normal. As soon as
the CCU main power switch is turned ON, the self diagnostic function starts running, and always runs during operation.
If the CCU or camera becomes abnormal, the diagnostic function immediately detects the abnormality, and the ALARM indicator
on the OCP or MCP ashes ON and OFF. Furthermore, the self diagnostic information screen appears on the PM, so that you can
locate the trouble point.
Note:
Even if the ALARM indicator does not ash, you can check whether CCU and camera are running normal by pressing the PM IND/
PAGE button on the OCP or on the MCP to display the self diagnostic screen on the PM.
OCP
O C P - 2 0 0
CAM PWR VF PWR
OFF
STANDARD
CAP
BARS
CAL
TALLY
INFO
OPE
SETUP
MAINTE
I
O
S
M
LENS EXT
FULL
RELATIVE
KNOB
FREE
HEAD POWER
RANGE
SENS
OPT
HEAD
CCU
CABLE
CLS OPEN
±1 ±2
OPEN
SHORT
ALARM
CALL
PREVIEW
For the list of self diagnostic information of CCU-970, refer to the relevant operation manual. Perform the appropriate action
referring to the list.
PM IND
PANEL
/ PAGE
ENABLE
PM IND/PAGE
AWB
ABB
button
AWB
ABB
USER WFM/PM
U
W
IRIS
ALARM
PED
indicator
HDK-790GX 1403 VER1 (U)
6.1 Alarm Lamp on the OCP or MCP Flashes ON and OFF
MCP
MIX
R
G
B
Y
SEQ
SUP
6
89

Advertisement

Table of Contents
loading

Table of Contents