6 Troubleshooting
Chapter 6
Troubleshooting
Troubleshooting
6.1 When the STATUS
indicator lights red
This device has a self-diagnosis function to monitor camera
failures. This function tur ns on when the power of the
device is turned on and keeps working while the device is in
operation.
Self-diagnosis information of the device
List of warnings
When any failure occurs for the following items, the device
outputs the warning status shown in the table.
Diagnosed
STATUS
result
indicator
Voltage in
Power supply
Red light
blinking
voltage status
indication
"TEMP!!"
Internal
Red light
in blinking
temperature status
indication
"FAN!!" in
Fan rotating status Red light
blinking
indication
"MEM
BATT
WARN" in
Memory battery
Red light
blinking
status
indication
for a few
seconds
STATUS indicator
red light
44
Screen
Description
display
The supplied voltage
is equal to or lower
than the set value.
The voltage to
start outputting
the warning is set
in "BATT WARN
VOLT" in the menu.
Internal temperature
too high
The fan has stopped.
The backup battery
voltage is low.
This indication
appears only when
the power is turned
on.
UHL-43 2005 VER1 (E)
MONITOR output
Caution
When a warning indication appears, check the warning
content. Then please respond properly or contact the nearest
6.2 Initializing the settings
of this camera
There are two methods to initialize the settings of this
camera.
① Initializing to the status set by the user
(ENGINEER SET FILE)
The camera is initialized to the setup which the user's
engineer set according to the operating environment and the
shooting status.
② Initializing to the factory default setup
(FACTORY SET FILE)
The camera is initialized to the default setting.
Initialization is performed using the Menu screen. The
following section describes the initialization method.
Camera initialization
1
On the main menu (TOP MENU), turn the MENU
Rotary Encoder (RE) to align the cursor to "FILE
OPERATION." Press the MENU RE to display
the sub menu.
Memory battery
status warning
Fan rotating status
warning
Internal temperature
status warning
Power supply voltage
status warning