The functions that are set in the ex-factory and the electrical connection data of all control
signal terminals are listed in the following table.

Factory-Set Control Terminal Functions

Terminal
Signal
1
+10V
Output nominal voltage
2
AI1
Analog signal input 1
3
GND
Reference potential
4
AI2
Analog input 2
5
GND
Reference potential
6
24V
Control voltage for DI1–DI6, output
(+24V)
7
DI-C
Reference potential of the digital
inputs DI1–DI6
8
DI1
Digital input 1
9
DI2
Digital input 2
10
DI3
Digital input 3
13
DO–
Digital output
14
DI4
Digital input 4
15
DI5
Digital input 5
16
DI6
Digital input 6
18
AO
Analog output
20
DO+
Digital output
22
R13
Relay 1, normally open contact
23
R14
Relay 1, normally open contact
24
R22
Relay 2, changeover contact
(N/C)
25
R21
Relay 2, changeover contact
26
R24
Relay 2, changeover contact
(N/O)
A
A
RS485 signal A
B
B
RS485 signal B
Note
Programmable function (see "List of Parameters" on Page 161).
40
M-Max Series Adjustable Frequency Drive MN04020003E—October 2013 www.eaton.com
Factory setting
Frequency reference value
PID controller, actual value
LOGIC- (GND)
FWD start enable, forward
REV start enable, reverse
Fixed frequency B0
Active = READY
Fixed frequency B1
Error acknowledgment
PI controller deactivated
Output frequency
Supply voltage, see control signal
terminal 13
Active = RUN
Active = RUN
Active = FAULT
Active = FAULT
Active = FAULT
BUS-communication
BUS-communication
Description
Maximum load 10 mA, reference potential GND
0–10V (R i >200k ohms)
0/4–20 mA (R B = 200 ohms)
Selectable through microswitch S2
0V
0–10V (R i >200k ohms)
0/4–20 mA (R B = 200 ohms)
Selectable through microswitch S3
0V
Maximum load 50 mA, reference potential GND
Selectable through microswitch LOGIC –/+
0–30V (R i >12k ohms)
0–30V (R i >12k ohms)
0–30V (R i >12k ohms)
Transistor, max. 50 mA, supply voltage control
signal terminal 20
0–30V (R i = 12k ohms)
0–30V (R i = 12k ohms)
0–30V (R i = 12k ohms)
0–10V, max. 10 mA
Supply voltage for digital output DO max. 48 Vdc,
max. 50 mA
Maximum switching load:
250 Vac/2A or 250 Vdc/0.4A
Maximum switching load:
250 Vac/2A or 250 Vdc/0.4A
Maximum switching load:
250 Vac/2A or 250 Vdc/0.4A
Maximum switching load:
250 Vac/2A or 250 Vdc/0.4A
Maximum switching load:
250 Vac/2A or 250 Vdc/0.4A
Modbus RTU
Modbus RTU