MMX-NET-XB
The MMX-NET-XB interface module enables the flush
mounting and connection of fieldbus interface cards to the
frequency inverters in frame sizes FS4 and FS5.
MMX-NET-XB Interface Module
Note: The MMX-NET-XB interface module is not supplied
with the M-Max frequency inverter.
Note: Detailed installation instructions are provided in
IL04012010Z.
The MMX-NET-XC interface module is fitted under the cover
on the right-hand side (view from front of the keypad) of the
MMX frequency inverter:
First remove the cover of the frequency inverter (4 screws)
●
Remove Cover (FS4, FS5)
T x 20
M-Max Series Adjustable Frequency Drive MN04020003E—October 2013 www.eaton.com
Accessories are provided with the MMX-NET-XB for fitting
the fieldbus interface card and interface module.
Mounting Accessories for FS4, FS5
04 = MMX, FS4
1 x
05 = MMX, FS5
To install, remove the screw in the bottom right corner of
●
the frequency inverter (chassis connection, board)
Then fit the metal bracket marked 04 (= FS4) or 05 (= FS5)
●
with this screw
At the top end of the metal bracket fasten the two metal
●
clips
The fieldbus interface cards with pluggable screw terminals
must be plugged in to support the terminals of the plastic
strip.
Plastic Bridge for Holding the Control Terminals
(For example: OPTE3 0 XMX-NET-PS-A)
1 x
Then connect the required fieldbus interface card to the
●
MMX-NET-XB interface module
Appendix A
1 x
2 x
OPTE3
155