Pid Controller - Eaton M-Max Series User Manual

Adjustable frequency drive
Hide thumbs Also See for M-Max Series:
Table of Contents

Advertisement

PID Controller

Access
PNU
ID
RUN
P9.1
163
P9.2
118
P9.3
119
P9.4
167
P9.5
332
P9.6
334
P9.7
336
P9.8
337
P9.9
340
P9.10
132
P9.11
1431
P9.12
1016
P9.13
1018
P9.14
1017
P9.15
1433
P9.16
1434
P9.17
1435
P9.18
1475
P9.19
1476
P9.20
1478
ro/rw
Designation
rw
PID controller
rw
PID controllers, P gain
rw
PID controller, I reset time
rw
PID controller setpoint, keypad
reference
rw
PID controller, setpoint source
rw
PID controller, process variable (PV)
source (Actual value or feedback)
rw
PID controller, actual value
limiting, minimum
rw
PID controller, actual value
limiting, maximum
rw
PID controller, controller
deviation
rw
PID controller, D rate time
rw
PID controller, output filter,
delay time
rw
Sleep mode, frequency
rw
Sleep mode, wake up setpoint
rw
Sleep mode, delay time
rw
Hysteresis, upper limit
rw
Hysteresis, lower limit
rw
PID controller, max. controller
deviation
rw
PID controller, reference value
scaling
rw
PID controller, process value
scaling
rw
PID controller, output signal
limit
M-Max Series Adjustable Frequency Drive MN04020003E—October 2013 www.eaton.com
Value Range
0 = Deactivated
1 = Activated for drive control
2 = Activated for external application
0.0–1000.0%
0.00–320.00s
0.0–100.0%
0 = Keypad unit (P9.4)
1 = Fieldbus
2 = AI1
3 = AI2
0 = Fieldbus
1 = AI1
2 = AI2
0.0–100.0%
0.0–100.0%
0 = Not inverted
1 = Inverted
0.00–10.0s
0.00–10.0s
0.00–P6.4 Hz
0.0–100.0%
0–3600s
0.0–100.0%
0.0–100.0%
0.0–100.0%
0.1–32.7
0.1–32.7
0.00–100.0%
Appendix A
FS
User
Page
(P1.3)
Setting
95
0
95
100.0
95
10.00
95
0.0
95
0
96
2
96
0.0
96
100.0
96
0
96
0.00
96
0.0
96
0.00
96
25.0
96
30
97
0.0
97
0.0
97
3.0
97
1.0
97
1.0
97
100.0
171

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents