Serial Interface (Modbus RTU)
General Control Word (ID 2002)
15
14
13
12
NB
NB
NB
NB
Speed Setpoint (ID 2003; Frequency Setpoint)
The permitted value range lies between 0 and 10.000. In the application, this value is scaled
to a percentage in the frequency range between the defined minimum and maximum
frequencies.
15
14
13
12
MSB
Output Process Data
The output process data is used to monitor the frequency inverter.
ID
Modbus Register
2101
32101, 42101
2102
32102, 42102
2103
32103, 42103
2104
32104, 42104
2105
32105, 42105
2106
32106, 42106
2107
32107, 42107
2108
32108, 42108
2109
32109, 42109
2110
32110, 42110
2111
32111, 42111
138
M-Max Series Adjustable Frequency Drive MN04020003E—October 2013 www.eaton.com
11
10
9
8
NB
NB
NB
NB
11
10
9
8
Designation
Fieldbus status word
Fieldbus general status word
Fieldbus actual speed
Motor frequency
Motor speed
Motor current
Motor torque
Motor power
Motor voltage
DC-link voltage (DC)
Current error
7
6
5
4
NB
NB
NB
NB
7
6
5
4
Value Range
0.01
0.01
1
0.01
0.1
0.1
0.1
1
3
2
1
0
NB
NB
NB
NB
3
2
1
0
LSB
Type
Binary code
Binary code
%
+/– Hz
–1
+/– RPM (min
)
A
+/–% (of the nominal value)
+/–% (of the nominal value)
V
V
Error code (E_)