Parameters
Digital Inputs, continued
Access
PNU
ID
RUN
P3.12
1020
P3.13
1400
—
P3.14
1401
P3.15
1402
P3.16
1403
P3.17
1404
P3.18
1405
P3.19
1406
P3.20
1407
P3.21
1408
74
M-Max Series Adjustable Frequency Drive MN04020003E—October 2013 www.eaton.com
Value/Range
Description
—
PID controller deactivate
Like P3.2
Allocation of the function to control signal terminals
When switching on +24V power, the PID controller is
blocked via the assigned control signal terminal (DI1 to DI6)
—
(Not used)
—
External brake, feedback signal (N/O)
Like P3.2
Assignment of control signal terminal
—
Change acceleration/deceleration time (acc 2/dec 2)
Like P3.2
Assignment of control signal terminal
Switch acceleration time from acc1 (P6.5) to acc2 (P6.19)
Switch deceleration time from dec1 (P6.6) to dec2 (P6.20)
—
Stop acceleration/deceleration time
Like P3.2
Assignment of control signal terminal
Stops all acceleration (P6.5, P6.19, P14.9) and deceleration
times (P6.6, P6.20, P14.10)
—
Block parameter access
Like P3.2
Assignment of control signal terminal
Blocks access to all parameters
Note: The resetting of all parameters to the default settings
via the STOP button (held down 5s) remains active
—
Motor potentiometer, increase value
Acceleration time, see "P6.5" (acc1)
Like P3.2
Assignment of control signal terminal
—
Motor potentiometer, decrease value
Deceleration time, see "P6.6" (dec1)
Like P3.2
Assignment of control signal terminal
—
Motor potentiometer, set value to zero
Like P3.2
Assignment of control signal terminal
—
PLC program start
Like P3.2
Assignment of control signal terminal
Factory Setting
(P1.3)
6
—
0
0
0
0
0
0
0
0