Checking The Starter Relay - KTM 400 EXC AUS 2011 Repair Manual

Hide thumbs Also See for 400 EXC AUS 2011:
Table of Contents

Advertisement

lllWlRING HARNESS, BATTERY
85
Cbeckinllhe stal1l!r
rela,
Info
I
Do not unplug the plug-in connection for the measurement.
-
Go through the steps of starting the engine. (
..
p. 10)
Regulator output voltage
Ground (brown) - yellow/red
13 ... 15 V
>
If the value displayed does not meet specifications:
-
Change the voltage regulator.
-
Switch off all power consumers and switch off the engine.
-
Remove the seat. (
..
p. 66)
-
Remove the air filter box lid. (
..
p. 64)
-
Disconnect the negative cable from the battery.
-
Pull the starter relay off of the holder.
-
Pull off connector
e.
-
Disconnect cables
e
and
e
on the starter relay.
-
Connect the starter relay to a 12 V power supply as shown.
-
Measure the resistance between the specified points.
I
Resistance of open circuit
Ion
>
If the value displayed does not meet specifications:
-
Change the starter relay.
lllWlRING HARNESS, BATTERY
85
Cbeckinllhe stal1l!r
rela,
Info
I
Do not unplug the plug-in connection for the measurement.
-
Go through the steps of starting the engine. (
..
p. 10)
Regulator output voltage
Ground (brown) - yellow/red
13 ... 15 V
>
If the value displayed does not meet specifications:
-
Change the voltage regulator.
-
Switch off all power consumers and switch off the engine.
-
Remove the seat. (
..
p. 66)
-
Remove the air filter box lid. (
..
p. 64)
-
Disconnect the negative cable from the battery.
-
Pull the starter relay off of the holder.
-
Pull off connector
e.
-
Disconnect cables
e
and
e
on the starter relay.
-
Connect the starter relay to a 12 V power supply as shown.
-
Measure the resistance between the specified points.
I
Resistance of open circuit
Ion
>
If the value displayed does not meet specifications:
-
Change the starter relay.