14. I/O Remote Settings

This section describes the functions and timings of input and output signals.
The remote functions may be assigned to your standard I/O board(s), or fieldbus I/O
board(s) to enhance robot system control - either from an operational unit of your choice
or a sequencer.
Remote function is initially assigned to both input and output from 0 to 7.
To accept external remote inputs, assign the remote function and the control device is
remote. For further details, refer to the section, Remote Control Software Configuration
in EPSON RC+ 7.0 User's Guide - Remote Control.
The user defines the I/O number that a remote function is assigned to using software
configuration.
Configuration in EPSON RC+ 7.0 User's Guide - Remote Control.
For details about I/O cable connection, refer to sections on Setup & Operation 13:
Standard I/O Connector and 17. Fieldbus I/O.
For details about communication with external equipment, refer to EPSON RC+ 7.0
User's Guide -12. Remote Control.
When using remote I/O, always make sure of the following. Using the robot
system under unsatisfactory conditions may cause malfunction of the system
and/or safety problems.
- Assign remote functions to inputs/outputs correctly and wire correctly when
- Make sure that the functions correspond to the correct input/output signals
CAUTION
When verifying the robot system operation, prepare for failures with initial
settings or wiring. If the Manipulator functions unusually by the failures with
initial settings or wiring, press the Emergency Stop switch immediately to stop
the Manipulator.
- Remote function is available when virtual I/O is enabled.
NOTE
- When you set up a remote I/O signal, please either keep a written record of the settings
or store the data in a file for later reference.
- When you set up a fieldbus I/O signal to the remote function, response depends on the
baud rate of the fieldbus. For details of fieldbus response, refer to the following manual.
VT Rev.1
For further details, refer to the section, Remote Control Software
setting up remote I/O signals.
before turning ON the system.
Robot Controller RC700 / RC90 Option Fieldbus I/O.
Setup & Operation 14. I/O Remote Settings