172.16.0.1
192.168.0.1
The following is the configuration of the controller Manipulator at delivery.
IP Address : 192.168.0.1
IP Mask
IP Gateway : 0.0.0.0

9.3 Changing Manipulator IP Address

In this section, the procedure to change the Manipulator IP address when connecting
Manipulator development PC connection port and the development PC by the USB cable
is indicated.
(1) For connection between the development PC and the Manipulator.
(2) Select the EPSON RC+ 7.0 menu-[Setup]-[Controller] to display the following dialog.
(3) Select [Controller]-[Configuration].
(4) Enter the proper IP address and subnet mask and click the <Apply> button.
(5) Click the <Close> button. The Manipulator reboots automatically.
VT Rev.1
Setup & Operation 9. LAN (Ethernet Communication) Port
Private Address List
10.0.0.1
to
10.255.255.254
to
172.31.255.254
to
192.168.255.254
: 255.255.255.0
Refer to Setup & Operation: 7. Development PC Connection Port.
IP address configuration is completed and the Manipulator reboot dialog disappears.