04.96
1129
Default value
0.8
cos is required for the calculation of the equivalent circuit diagrams from the data on the
rating plate.
Note:
This machine data only applies to main spindle drives.
1130
Default value
0.0
Input of motor rated power as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
Note:
This data is relevant only for MSD drives.
1132
Default value
380.0
Input of motor rated voltage as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102).
1134
Default value
50.0
Input of motor rated frequency as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102).
Note:
This data is relevant only for MSD drives.
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
cos power factor
Lower input limit
Upper input limit
0.0
Motor rated power
Lower input limit
Upper input limit
0.0
Motor rated voltage
Lower input limit
Upper input limit
0.0
Motor rated frequency
Lower input limit
Upper input limit
0.0
6FC5197- AA50
7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
Units
1.0
Units
1 500.0
kW
Units
5 000.0
Units
3 000.0
Active on
Power On
Active on
Power On
Active on
Power On
V
Active on
Power On
Hz
7–93