Siemens SINUMERIK 840C Installation Instructions Manual page 449

Siemens computer drive installation instructions
Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

7 Drive Machine Data (SIMODRIVE Drive MD)
7.1.2 MSD MD (data description - SW 3)
238
Default value
101
Note:
This machine data is not included in the machine data lists. During start-up in machine data
dialog, the machine data is set or altered as appropriate via the configuration setting.
Input of code number for the motor used. The relevant motor data are stored in the software
and are transferred to machine data MD 219 to MD 235 when the motor code number is
changed. If individual motor data (MD 219 to MD 235) must be changed, then the value 99
(non-Siemens motor) must be entered as the motor code number.
See machine data MD 96 for table of motors.
241
Default value
2
A function can be assigned to programmable message 1 in this machine data. The range of
available functions is listed in the table below.
The default setting corresponds to Ramp-up complete.
Table of functions:
Function
| n
| < n
act
min
Ramp-up complete
| M
| < M
d
dx
| n
| < n
act
x
Motor overtemperature
prewarning
Heat sink overtemperature
prewarning
Variable relay function 1
(MD 185 - MD 189)
Variable relay function 2
(MD 190 - MD 194)
n
= n
act
set
7–34
Motor code number motor 2
Lower input limit
Upper input limit
99
Programmable message 1
Lower input limit
Upper input limit
1
Function number
(setting value of
MD 241 ... MD 246)
1
2
3
4
5
6
7
8
20
©
Siemens AG 1992 All Rights Reserved
Power On
Units
332
Units
20
Default setting of
MD 241 ... MD 246
MD 243
MD 241
MD 242
MD 244
--
--
MD 246
--
MD 245
6FC5197- AA50
SINUMERIK 840C (IA)
10.94
Active on
Active
at once