09.95
Measuring circuit assignment 2nd measuring system
1388*
Default value
Lower input limit
0
Active:
After POWER ON.
Only applies to feed axes.
The second measuring system is defined in the same way as the first measuring system with
MD 200*.
Feedforward control factor 8th parameter set
1392*
Default value
0
This MD has the same meaning as MD 312*, see also functional description of parameter set
switchover.
1396*
Default value
1
NC MD 1396* modifies NC MD 155 "Position controller sampling time", i. e. the controller can
be slowed down by a factor of 2 to 64.
Permissible values:
1, 2, 4, 8, 16, 32, 64
The following applies:
Position control cycle time = Position control basic cycle x MD 1396*
Interpolation cycle
Conditions:
–––––––––––––––––––– >1 (integer)
Axial pos. control cycle
See also MD 466*
1420*
Default value
0
Note:
As from SW 4, for 8 parameter sets
1424*
Default value
0
Note:
As from SW 4, for 8 parameter sets
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
6 NC Machine Data (NC MD), NC Setting Data (NC SD)
(as from SW 2)
Upper input limit
5030000 analog (as from SW 2)
0
15021000 (as from SW 3)
30021000 (as from SW 5)
(as from SW 4)
)
Lower input limit
+0
Position control cycle
Lower input limit
1
P component compensatory controller
Lower input limit
0
I component compensatory controller
Lower input limit
0
6FC5197- AA50
6.7 Axis-specific MD 2 (axial data 2)
Upper input limit
1 000
Upper input limit
64
Upper input limit
16 000
Upper input limit
16 000
Active on
Power On
Units
Active on
NC Stop
Units
0.1 %
Active on
Power On
Units
Active on
NC Stop
Units
1
Active on
NC Stop
Units
1