6 NC Machine Data (NC MD), NC Setting Data (NC SD)
6.10 MDs for flexible memory configuration
60011
Memory configuration of NC module as from SW 4
Default value
0
Machine data reserved by the system.
60012
Default value
0
This machine data is used simply to indicate the CPU loading. For a description, refer to the
section entited "Installation of axis and spindle".
60013
Default value
15
This MD is used to define the memory for real axes (> 15). If the user has defined more real
axes than memory is available, alarm 71 is displayed.
Number of memory blocks for drive software
60014
Default value
0
Memory for drive software MSD/FDD 0/2/3/4/6 blocks of 96 Kbytes each, see also machine
data 60003 and 60004.
6100*
Default value
23
This MD is used to define channel-specifically the maximum number of part program blocks
that can be predecoded during execution.
See "Flexible memory configuration" functional description.
6–214
Lower input limit
Upper input limit
Load cap. of NC CPU (as from SW 5)
Lower input limit
Upper input limit
-
Memory for real axes (as from SW 5)
Lower input limit
Upper input limit
15
(as from SW 6)
Lower input limit
Upper input limit
0
Channel 1 to channel 6 as from SW 4
Lower input limit
Upper input limit
0
©
Siemens AG 1992 All Rights Reserved
"Reconfigure
Units
Byte
Units
100
%
Units
30
approx. 16 KB/axis
Units
6
96 Kbytes
"Reconfigure
Units
3 450
1 block buffer
6FC5197- AA50
SINUMERIK 840C (IA)
07.97
Active
after SK
memory"
Active
At once
Active
Power On
Active
Power On
Active
after SK