Siemens SINUMERIK 840C Installation Instructions Manual page 275

Siemens computer drive installation instructions
Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

6 NC Machine Data (NC MD), NC Setting Data (NC SD)
6.6.1 General MD bits (general bits)
Bit 2
Bit 2 = 0,
Auxiliary function output during axis movement
Bit 2 = 1,
Auxiliary function output prior to travel
Active:
If an auxiliary function (M, S, T, H, D) is also programmed in a traversing block,
bit 2 can bring about the following two states:
Example:
N10
N15
M6
X100
N20
Bit 1=1
If the bit is set, the internal WAIT mark synchronization is active.
Bit 1=0
WAIT mark synchronization via PLC
Active: NC STOP
Note:
Observe the internal WAIT MARK SYNCHRONIZATION DB 10-15 DL 15.8 interface signal as
from SW 6.3
Bit 0=1
No NC STOP in dwell block G04 S.../G14/G24. NC STOP is not active in
these blocks, but only at the end of the block.
Bit 0=0
NC STOP is immediately active; the dwell time and thus the block are aborted
completely. The next block is started with NC START.
Active: NC STOP
Note
A dwell time with G04 x..., G04 F... is always aborted by NC STOP.
6–90
NC Stop
L F
(V)
Velocity
N10
M6
(V)
N10
M6
©
Siemens AG 1992 All Rights Reserved
Bit 2 = 0
N15
N20
(t)
Bit 2 = 1
(t)
PLC cycle
SINUMERIK 840C (IA)
01.99
6FC5197- AA50

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents