Creating a file in the SERVICES area
Select the SERVICES area.
SERVICES
Press the MANAGEMENT softkey.
MANAGEMENT
Press NEW softkey.
NEW
Select PLC in the directory of all possible subdirectories in the user branch using
the cursor keys and accept with INPUT.
Position the cursor on DATA and accept with INPUT.
The directory of all available languages is displayed.
You select the required language directory using the cursor keys and accept with
INPUT.
A directory of files which have been stored under the selected language is dis-
played.
Creating a new file
Press softkey NEW.
NEW
You can then enter any name (maximum 8 characters) in the input field.
The input is accepted with INPUT and OK.
If PCF is not used as the identifier, this file is not loaded into the NCK on POWER
ON.
These files can be loaded into the NCK memory using the softkey function LOAD
in the DIAGNOSIS area.
Operating sequence
The area DIAGNOSIS PLC DATA MANAGEMENT/DEUTSCH is selected in the
LOAD
user area.
Select the files to be transferred using the cursor and the input key.
Siemens AG 2001 All Rights Reserved 6FC5197–jAA50
SINUMERIK 840C (IA)
If the PCF file is to be loaded into the NCK memory or run-
up according to the entry in the KONFIG file (language),
then the identifier PCF ... must be used.
4 MMC Area Diagnosis
4.8.3 PCF files (up to SW 2)
4–61