12.93
Bit 0
Bit 0 = 0
Inhibits auxiliary function output to the PLC
Auxiliary functions are: M, S, T, H, D. Use is recommended for
computational channels.
For output of the programmed F value to the PLC, see NC MD 544*,
bit 0.
Note:
In machining channels bit 0 must always be "1".
Active:
NC MD
7
542*
All auxiliary functions M, S, T, D, H and F are always output to the PLC under acknowledge-
ment control.
For slow auxiliary function output (bits 0 to 3 = 0), the auxiliary function is not acknowledged
by the PLC until the cyclic user program (UB1) has been run once.
For fast auxiliary function output (bits 0 to 3 = 1), the auxiliary function is acknowledged by
the PLC already after the basic program has been run once. The auxiliary function can be
safely recognized in the PLC user program, but read-in disable, feed hold, etc. cannot take
effect in the same NC block.
Bit 0 to 3=1
Fast auxiliary function output to the PLC
Bit 0 to 3=0
Slow auxiliary function output to the PLC (default setting).
Active:
Notes:
The auxiliary functions M and H can be declared as fast auxiliary functions by
programming "–" (e.g. M-03) (see Programming Guide).
If several auxiliary functions are programmed in one block, all auxiliary functions must be
parameterized as fast auxiliary functions so that output to the PLC is "fast". This also
applies to the F word even if it is not transferred to the PLC (see MD 544*, bit 0).
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
6 NC Machine Data (NC MD), NC Setting Data (NC SD)
In the next block
Bit No.
6
5
4
Fast auxiliary function output to the PLC
Immediately
6FC5197- AA50
6.6.3 Channel-specific MD bits 1 (channel bits)
3
2
1
T
S
F
0
D
6–137