Siemens SINUMERIK 840C Installation Instructions Manual page 563

Siemens computer drive installation instructions
Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
1650
Default value
0000
Input to select a variety of diagnostic functions in the diagnostic control word.
Caution:
This machine data is relevant only for Siemens-internal purposes and must not be altered.
Value table:
Bit 0
Min/max memory
Bit 1
Segment min/max memory
Bit 2
Comparison with sign
Bits 3-7
Not assigned
Bit 8 (up to
Voltage-controlled V
SW 4.4)
Bit 9
Reserved
Bits 10-15
Not assigned
Notes:
Bit 1 is effective only if signal number 0 is selected in MD 1651 (signal number min/max
memory).
Diagnostic function "Min/max memory"
This function can be used to calculate the value range within which a specific memory
location moves over a prolonged period. The function is executed in the current controller
cycle (fastest cycle) in order to ensure reliable detection of all system quantities.
The quantity to be monitored can be selected through specifying either a signal number or
a physical address (see MD 1651).
The comparison of the value with the maximum and minimum values can be implemented
either with or without sign (bit 2).
Corresponding machine data are as follows:
Diagnosis control (MD 1650, bits 0, 1, 2)
Signal number min/max memory (MD 1651)
Memory location min/max memory (MD 1652)
Minimum value min/max memory (MD 1653)
Maximum value min/max memory (MD 1654)
7–148
Diagnosis control
Lower input limit
Upper input limit
0000
operation
q
©
Siemens AG 1992 All Rights Reserved
Units
FFFF
Hex
0 = not active
1 = active
0 = DSP address name X
1 = DSP address name Y
0 = without sign
1 = with sign
0 = normal operation
1 = V
operation active
q
6FC5197- AA50
SINUMERIK 840C (IA)
04.96
Active
at once

Hide quick links: