Advertisement

5 Machine Data Dialog (MDD – as from SW 3)
5.1.1 General notes on operation
Current controller:
MD 1120
MD 1121
Flux controller:
MD 1150
MD 1151
Torque and output limits:
MD 1230
MD 1235
Speed interface normalization:
MD 1401
Speed controller:
MD 1147
MD 1405
MD 1407
MD 1408
MD 1409
MD 1410
MD 1411
MD 1412
MD 1413
AM operation:
MD 1451
MD 1453
MD 1466
MD 1465
MD 1608
v/f operation:
MD 1127
Selecting displayed data in header (SW 4 and higher)
+
You select the displayed parameter number (top left) for position control, ratio
and drive and the displayed axis number for the axis by pressing the Shift and
the Home hardkeys simultaneously.
Explanation
With these keys it is possible to enter the data directly in all displays in which the
current data are displayed in the header. It is also possible to toggle and move
forwards/backwards with the +/– and select keys. The cursor remains positioned
on the parameter number in the header until either a correct number has been
entered or the Enter, Shift-Home, Backspace, Delete, Cursor key has been
operated and the field is exited without making any changes.
Note
This function replaces the previous Search local function for IKA 2 (IKA curve
pointer) and IKA 3 (IKA error points).
Example of application:
Copy to
Copying data from one axis into another axis.
clipboard
Paste from
clipboard
5–6
P gain current controller (FDD/MSD)
Reset time current controller (FDD/MSD)
P gain flux controller (MSD)
Reset time flux controller (MSD)
1st torque limit (FDD)
1st output limit (FDD)
Speed for max. motor working
speed (FDD/MSD)
Speed limitation (FDD/MSD)
Monitoring speed motor (FDD/MSD)
P gain speed controller (FDD/MSD)
P gain upper adaptation speed (MSD)
Reset time speed controller (FDD/MSD)
Reset time upper adaptation speed (MSD)
Lower adaptation speed (MSD)
Upper adaptation speed (MSD)
Selection adaptation speed controller (MSD)
P gain speed controller AM (MSD)
Integral action time speed controller AM (MSD)
Changeover speed closed/open loop control AM (MSD
Changeover speed MSD/AM (MSD only when MD 1011.5=1)
Fixed temperature (MSD only when MD 1011.5=1)
Voltage with f=0 V/F-mode (MSD)
Please note that any controller data entered manually will
be overwritten when softkey Calculate controller data is
pressed!
Siemens AG 2001 All Rights Reserved 6FC5197–jAA50
09.95
SINUMERIK 840C (IA)