01.99
09.95
Backup menu tree
1
Restore/backup (first install correct streamer with Item 2/Item3 set streamer type)
1
Install MMC system
When you select menu item 1, new MMC software, SW options (e.g. graphic program-
ming) or software updates are transferred to and installed on the hard disk.
2
Backup system
With the 2nd menu item it is possible to perform a complete system BACKUP, i.e. all
the software (operating system – software, user software and software options) are
transferred from the hard disk to the streamer.
3
Restore system
With the function SYSTEM RESTORE it is possible to transfer a complete previous
BACKUP from the streamer to the hard disk of the MMC CPU. Any existing user data
of the same name are overwritten.
Note:
Other user data are not deleted.
4
Backup user data
With the function BACKUP USER DATA all data in the user branch are transferred
from the hard disk to the streamer.
5
Restore user data
With the function RESTORE USER DATA it is possible to transfer a complete previous
BACKUP copy of the user data from the streamer onto the hard disk of the MMC CPU.
Any existing user data of the same name are overwritten.
Note:
Other user data are not deleted.
6
Free data transfer
1
2
3
4
Note:
Up to SW 4, menu item 6 exists under the designation Setup Streamer. This menu
item is installed for service only and is password-protected. For further information
please refer to the VALITEK MANUAL. This menu item must not be used to select the
type of streamer!
7
Uninstall MMC system
8
Set streamer device
9
Return to main menu
Siemens AG 2001 All Rights Reserved 6FC5197–jAA50
SINUMERIK 840C (IA)
Uninstall NCK
If you select the function UNINSTALL NCK the entire NCK system software
is erased from the hard disk.
Uninstall PG software
If you select the function UNINSTALL PG software, the PG software is
erased.
Uninstall the complete system
If you select the function UNINSTALL THE COMPLETE SYSTEM the entire
system software and all user data are erased.
Return to previous menu
4 MMC Area Diagnosis
4.6 BACKUP with Valitek streamer/PC link
4–53