09.95
1113
Default value
5
Input of torque constant as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102). The torque
constant is the quotient of rated torque : rated current (RMS) for permanent-field synchronous
motors.
1114
Default value
0
Input of voltage constant as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102). The voltage
constant is measured as an induced voltage (EMF) under no-load conditions at n = 1000
rev/min as the RMS value of the motor terminals (line-to-line).
1115
Default value
0
Input of ohmic resistance of the armature winding (phase value) as specified on the motor data
sheet (non-Siemens motor) or automatic parameterization using machine data "Motor code
number" (MD 1102).
1116
Default value
0
Input of armature rotating-field inductance as specified on the motor data sheet (non-Siemens
motor) or automatic parameterization using machine data "Motor code number" (MD 1102).
1117
Default value
0
Input of motor moment of inertia as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102 - in motors
without a holding brake).
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
Torque constant
Lower input limit
Upper input limit
0.1
Voltage constant
Lower input limit
Upper input limit
1
Armature resistance
Lower input limit
Upper input limit
0
Armature inductance
Lower input limit
Upper input limit
0
Motor moment of inertia
Lower input limit
Upper input limit
0
32 (as from SW 5)
6FC5197- AA50
7 Drive Machine Data (SIMODRIVE Drive MD)
7.2.2 FDD MD (data description - SW 3)
Units
5
Nm/A
Units
300
V
Units
20
V/A
Units
100
mH
Units
kgm
Active on
Power On
Active on
Power On
Active on
Power On
Active on
Power On
Active on
Power On
2
7–55