Loading Machine Data (As From Sw 3) - Siemens SINUMERIK 840C Installation Instructions Manual

Siemens computer drive installation instructions
Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

2 General Reset and Standard Start-Up

2.6 Loading machine data (as from SW 3)

2.6
Loading machine data (as from SW 3)
Note
Loading the machine data function takes several seconds and is accompanied by
the flashing message "Wait".
Selection
The following softkeys must be pressed: Diagnosis, Startup, Machine data, File
functions:
Fig. 2.2
Procedure
Initial start-up
On initial start-up (state as supplied from Siemens), no files are available in the
"User data" window(see Fig.).
Subsequent start-up
On subsequent start-up, user files from the "User data" window can be loaded
instead of the files STANDD_T, STANDD_M, STANDARD in the "Standard data"
window.
Make sure that no communication is taking place with the digital drive systems. If
the user file contains drive data (TEA3), you must acknowledge the drive-specific
2-8
Step
Operation
1
Activate the standard
data window with the
2
Select STANDD_T or
STANDD_M
3
SK Load from disk
4
Select STANDARD
5
SK Load from disk
Siemens AG 2001 All Rights Reserved 6FC5197–jAA50
Comment
The window has a yellow border
key
NC-MD
PLC MD, cycl. MD
09.95
The MD in the NCK
area are cleared
and assigned stan-
dard values
dard values
SINUMERIK 840C (IA)