Advertisement

Code Description
5131 FBA STATUS
Contains the status of the adapter module.
0 =
– Adapter not configured.
IDLE
1 =
.
EXEC
INIT
2 =
TIME OUT
the adapter and the drive.
3 =
CONFIG ERROR
• The major or minor revision code of the adapter's CPI firmware
revision differs from that stated in the drive's configuration file.
4 =
-
OFF
LINE
5 =
-
ON
LINE
6 =
– Adapter is performing a hardware reset.
RESET
5132 FBA CPI FW REV
Contains the revision of the module's CPI program. Format is xyz,
where:
• x = major revision number
• y = minor revision number
• z = correction number.
Example: 107 = revision 1.07
5133 FBA APPL FW REV
Contains the revision of the module's application program. Format is
xyz, where:
• x = major revision number
• y = minor revision number
• z = correction number.
Example: 107 = revision 1.07
The new settings will take effect when the drive is next powered
up, or when parameter 5127 is activated.
Drive control parameters
After the fieldbus communication has been set up, the drive
control parameters listed in the tables below should be checked
and adjusted where necessary.
The "Setting for fieldbus control & description" column gives the
value to use when the fieldbus interface is the desired source or
destination for that particular signal as well as a description of
the parameter.
The fieldbus signal routes and message composition are
explained later in section
136
– Adapter is initializing.
– A time-out has occurred in the communication between
– Adapter configuration error.
– Adapter is off-line.
– Adapter is on-line.
Fieldbus control
ACH550 User's Manual
Range
0...6
0...0xFFFF
0...0xFFFF
interface.
Serial communications