Supplemental Information; Laser Setup - Omron LD Platform User Manual

Mobile robot platform
Table of Contents

Advertisement

4.4  Supplemental Information
The limits and defaults for these parameters are listed in the following table.
a: Although the Min value, in software, is -2500, the hardware safety system on the platform will
generate a fault if the velocity is anything from -300 to -2500 mm/s.

4.4 Supplemental Information

Laser Setup

For most installations, the defaults for the lasers should be appropriate, and will not require
any user adjustment.
The specific parameters for these lasers will come in the model config file that ships on the
unit, or can be provided on request if needed.
Laser_1 Settings are for the main scanning laser (S300), used both for safety and loc-
l
alization.
Laser_2 Settings are for the low front laser (TiM).
l
Laser_3 Tilted and Laser_4 Tilted are for the side lasers (TiM).
l
50
Parameter
AbsoluteMaxTransVel (LD-60)
AbsoluteMaxTransVel (LD-90)
AbsoluteMaxTransNegVel (LD-60)
AbsoluteMaxTransNegVel (LD-90)
AbsoluteMaxTransAccel
AbsoluteMaxTransDecel
AbsoluteMaxRotVel
AbsoluteMaxRotAccel
AbsoluteMaxRotDecel
LD Platform OEM User's Guide
Default
Min
Max
1800
1
2500
1350
1
2500
a
-280
-2500
-1
a
-210
-2500
-1
1000
1
2000
2000
1
2000
180
1
180
360
1
360
360
1
360
11970-000 Rev H1

Advertisement

Table of Contents
loading

Table of Contents