Docking Station Internal Fuse - Omron LD Platform User Manual

Mobile robot platform
Table of Contents

Advertisement

The fuses are available from the factory as p/n 02212-000L. Equivalent fuses are available gen-
erically. The fuses need to be 250 V, 10 A, and Time-lag. An example of a fuse that meets this
is:
LittelFuse 0215010.XP, 5x20 mm cartridge type

Docking Station Internal Fuse

NOTE: The following procedure applies only to legacy docking stations. There are
no user-serviceable fuses on the current docking station.
Symptoms: When the docking station is switched on, the blue power light does not come on,
but the docking station can charge a battery manually.
1. Remove the ten screws from the back cover of the docking station.
Two of these are on the sides, near the bottom.
11970-000 Rev H1
Figure 8-8. Docking Station Fuse
WARNING: Unplug power from the docking station before starting. The dock-
ing station cover is NOT interlocked. Remove the power cord at the charger.
LD Platform OEM User's Guide
Chapter 8: Maintenance
111