Rep 14.1 Scanner Assembly - Xerox Phaser 3635MFP Service Manual

Hide thumbs Also See for Phaser 3635MFP:
Table of Contents

Advertisement

REP 14.1 Scanner Assembly

Parts List on
PL 14.10
(3635),
PL 14.11
Removal
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Before performing this procedure, refer to
1.
Remove the DADF,
PL 5.10 Item
1.
2.
3635 only. Remove the UI assembly,
3550 only. Remove the UI assembly,
3.
Lock the CCD carriage.
4.
Remove the rear cover assembly, left cover and right cover,
5.
3635 only. Disconnect the following connectors from the
CN1
CN4
CN5
CN8
CN9
CN10
CN12
3550 only. Disconnect the following connectors from the
CN8
CN16
CN20
CN21
CN31
NOTE:
Figure 1
illustrates a Phaser 3635 MFP type scanner. However, the removal pro-
cedure is identical for the WorkCentre 3550 machines.
Phaser 3635MFP/WorkCentre 3550
(3550)
CAUTION
GP 10 General Disassembly
Precautions.
REP
2.1.
REP
2.3.
REP
28.1.
Main
PWB:
Main
PWB:
6.
Remove the scanner assembly,
1
Remove 1 screw.
4
Withdraw the UI harnesses through
the hole in the frame, then remove the
scanner assembly.
Figure 1 Scanner assembly removal
Replacement
1.
Replacement is the reverse of the removal procedure.
2.
3635 only. When reconnecting the ribbon cable to the main board (CN8) the blue flash
should face down.
April 2010
4-35
Figure
1.
2
Remove 2 screws
from the rear.
3
Remove 2 screws.
Repairs and Adjustments
REP 14.1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 3550

Table of Contents