10-100, 200 Open Fuser Error/Low Heat Error RAP
10-100 During normal operation, the temperature of the fuser has dropped below the operating
level.
10-200 The fuser has failed to reach the correct operating temperature.
Procedure
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
WARNING
Do not touch the fuser while it is hot.
Refer to
Wiring Diagram
1. Perform the following:
1.
Switch off the machine, then switch on the machine.
2.
Check that ACL is available between pins 1 and 2 on CON2. If ACL is not available, install
a new SMPS,
PL 1.12 Item
3.
3.
Enter
dC330 Component Control
code 10-100 to heat the fuser to 180 degrees. Enter
code 10-200 to verify the condition of the thermistor.
4.
Check the voltage at the thermistor on the
26 pin 1. When the fuser is cold it will read approximately 3.17 volts, then at power on the
voltage should decrease to approximately 1.8 volts. At operational temperature the volt-
age will remain at 2.0 volts.
5.
Switch off the machine. Remove the fuser assembly. Check that the thermistor,
Item 16
is clean and in good contact with the fuser heat roll. Check the wiring to the ther-
mistor. If necessary install a new thermistor,
6.
Check for continuity between the two pins on the fuser assembly connector,
Item
15.
NOTE: A cold fuser has a resistance of approximately 9 ohms (220V/240V) or 1.6 ohms
(110V).
7.
Check that there is continuity through the fuser heat lamp,
the thermostat,
PL 10.12 Item
18. Install new components as necessary.
8.
3635 only. Check the wiring between the following connectors:
a.
The fuser connector,
PL 10.12 Item 15
b.
The fuser connector,
PL 10.12 Item 15
If necessary, install a new fuser connector,
9.
3550 only. Check the wiring between the following connectors:
a.
The fuser connector,
PL 10.12 Item 15
b.
The fuser connector,
PL 10.12 Item 15
If necessary, install a new fuser connector,
10. If necessary:
a.
Install new components:
Fuser assembly,
PL 10.10 Item
SMPS,
PL 1.12 Item
3.
b.
Perform
OF7 Main PWB Check
Phaser 3635MFP/WorkCentre 3550
Main PWB
at, (3635) CN19 pin 1 or (3550) CN
PL 10.12 Item
16.
PL 10.15 Item 12
and CON2 on the SMPS.
and CN19 on the
Main
PWB.
PL 10.12 Item
15.
and CON2 on the SMPS.
and CN26 on the
Main
PWB.
PL 10.12 Item
15.
1.
RAP.
10-300 Over Heat Error RAP
10-300 The fuser temperature has risen above the normal level. Although the fuser unit can
return to a normal operating temperature, the fuser may consequently be damaged.
Procedure
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Do not touch the fuser while it is hot.
Go to the relevant procedure:
3635 Checkout
3550 Checkout
3635 Checkout
Refer to
Wiring Diagram
1.
Enter code
dC330 Component Control
to verify the condition of the thermistor.
2.
Check the voltage at the thermistor on the
cold it will read approximately 3.17 volts, then at power on the voltage should decrease to
approximately 1.8 volts. At operational temperature the voltage will remain at 2.0 volts.
3.
Make sure the fuser fan is working correctly, refer to the
that the machine is positioned to allow adequate airflow, refer to
PL 10.12
Requirements.
4.
Switch off the machine. Remove the fuser assembly. Examine the fuser assembly for heat
damage. Install new components as necessary,
PL 10.12
5.
Check that the thermistor,
Check the wiring to the thermistor. Check the crimp and weld quality between the wire
and thermistor terminal. Install a new thermistor if necessary,
6.
Check that there is continuity through the fuser heat lamp,
and across
the thermostat,
PL 10.12 Item
7.
Check the wiring between the following connectors:
a.
The fuser connector,
b.
The fuser connector,
If necessary, install a new fuser connector,
8.
If necessary:
a.
Install new components:
Fuser assembly,
SMPS,
PL 1.12 Item
b.
Perform
OF7 Main PWB Check
3550 Checkout
Refer to
Wiring Diagram 1
1.
Enter code
dC330 Component Control
to verify the condition of the thermistor.
April 2010
2-35
WARNING
WARNING
1. Perform the following:
code 10-200. Perform a fuser temperature check
Main PWB
at CN19 pin 1. When the fuser is
OF3 Air Systems
PL
10.10,
PL 10.12
PL 10.12 Item
16, is clean and in good contact with the fuser.
PL 10.15 Item 12
18. Install new components as necessary.
PL 10.12 Item 15
and CON2 on the SMPS.
PL 10.12 Item 15
and CN19 on the
PL 10.12 Item
15.
PL 10.10 Item
1.
3.
RAP.
and
Wiring Diagram 12
(3550). Perform the following:
code 10-200. Perform a fuser temperature check
10-100, 200, 10-300
RAP. Ensure
GP 13 Installation Space
and
PL
10.15.
PL 10.12 Item
16.
and across
Main
PWB.
Status Indicator RAPs