Gp 13 Installation Space Requirements - Xerox Phaser 3635MFP Service Manual

Hide thumbs Also See for Phaser 3635MFP:
Table of Contents

Advertisement

GP 13 Installation Space Requirements

Purpose
To outline the general space requirements to enable safe use and adequate access for service.
WARNING
Do not work in a confined space. 1 m (39 inches) space is needed for safe working.
WARNING
USA and Canada. Do not install this machine in a hallway or exit route that does not
have 1.12 m (44 inches) of space additional to the normal space requirements in front of
the machine. To conform with fire regulations this additional 1.12 m (44 inches) of space
is needed in front of the machine in hallway and exit routes.
Procedure
Refer to the following:
Machine Height
Machine Weight
Machine Dimensions and Installation Space Requirements
Machine Height
Basic Machine
Machine with the DADF lowered = 535mm (21 inches)
Machine with the DADF raised = 765mm (30.1 inches)
Machine with Two Trays
Machine with the DADF lowered = 662mm (26 inches)
Machine with the DADF raised = 892mm (35.1 inches)
Machine with Two Trays and Stand
Machine with the DADF lowered = 1103mm
Machine with the DADF raised = 1333mm
Machine Weight
Basic machine = 28.9Kg (63.5lb)
Tray 2 = 7Kg (15.4lb)
Stand = 14.8Kg (32.6lb)
Machine Dimensions and Installation Space Requirements
Table 1
shows the dimension of the machine and the installation space required for safe oper-
ation.
Phaser 3635MFP/WorkCentre 3550
NOTE: The dimensions shown in
workspace around the machine. To acquire the minimum safety workspace it may be neces-
sary to move the machine within the area specified.
Figure 1
represents a plan view of a machine installation and is to be read in conjunction with
Table
1. The dimensions A and B outline a footprint of the machine within the boundary of safe
operation, dimensions C and D. The dimension E indicates the area required for airflow / work-
space at the rear of the machine.
Table 1 Working space requirements
Machine
Machine width
depth
(A)
3635
472mm
488mm
(18.7inches)
(19.1 inches)
3550
582mm
488mm
(23 inches)
(19.2 inches)
NOTE: The machine depth dimension does not include the stand stabilizing feet.
April 2010
6-21
Table 1
allow for a 1 metre (39.4 inches) minimum safety
Install width
Install depth
required
required
service workspace
(B)
(C)
(D)
1472mm
1488mm
(58.4 inches)
(58.4 inches)
1582mm
1488mm
(58 inches)
(58.5 inches)
Front
Figure 1 Installation plan
General Procedures/Information
Install airflow/
(E)
178mm
(7 inches)
178mm
(7 inches)
GP 13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 3550

Table of Contents