Table 7 Fuser operating temperatures
Environment (Up to 100 prints/up to 150 prints/after 151 prints)
Machine State or
Paper Type
LL
Machine in standby 170 deg. C
Plain
185/185/189 deg. C
Recycled
197/193/189 deg. C
Thick/Bond
197/194/194 deg. C
Thin
180/180/180 deg. C
Envelope
180/178/176 deg. C
Cardstock/Label
198/195/192 deg. C
OHP
150/148/146 deg. C
The environment acronyms are as follows:
•
LL - Low temperature/low humidity.
•
NN - Normal temperature/normal humidity.
•
HH - High temperature/high humidity.
Table 8 HVPS Output
HVPS Output
Transfer High Voltage+ (THV+)
Transfer High Voltage- (THV-)
Charge Voltage (MHV)
Developing Voltage (DEV)
Supply
OPC
Fuser Bias
Phaser 3635MFP/WorkCentre 3550
NN
HH
165 deg. C
160 deg. C
180/180/178 deg. C
186/183/180 deg. C
194/191/187 deg. C
186/183/180 deg. C
195/193/189 deg. C
188/185/182 deg. C
175/175/175 deg. C
170/169/167 deg. C
170/168/165 deg. C
153/151/150 deg. C
190/185/180 deg. C
187/184/181 deg. C
144/142/140 deg. C
138/136/135 deg. C
Voltage
+1300V DC +/-3%
-1200V DC +/-20%
-1350V DC +/-20%
-330V DC +/-3%
-530V DC +/-3%
-130V DC +/-15%
+320V DC +/-3%
GP 8 DADF Document Feeding Specifications
Purpose
To list the specifications of the documents that can be fed through the DADF.
Specifications
Refer to
Table
1.
Item
Length
Width
Weight
Thickness
Curl
Input tray capacity
April 2010
6-17
Table 1 Specifications
Specification
145mm - 356mm (5.75 inches - 14inches)
69.9mm - 216mm (2.75 inches - 8.5 inches)
50gsm - 120gsm (12.5lb - 28lb)
0.07mm - 0.13mm
Less than 5mm
50 sheets of 80gsm (20lbs) paper
General Procedures/Information
GP 7, GP 8