A. Technical appendix
A.1

Technical data

A.1.1 General properties

General properties

Protection class through housing
To IEC/EN 60529, bus node fully mounted, plug
connector inserted or provided with protective
cap
Protection against electric shock
Protection against direct and indirect contact in
accordance with IEC/EN 60204-1
Separation
Bus signals,
DeviceNet interface to U
Electromagnetic compatibility (EMC)
– Emitted interference
– Resistance to interference
Temperature range
Ambient temperature
– Operation
– Storage/transport
Relative air humidity
To IEC 60770
Corrosion protection
1)
Note that the connected devices may conform to a lower protection class or a lower temperature
range etc.
2)
The bus node is intended for use in an industrial environment.
Outside of industrial environments, e.g. in commercial and mixed-residential areas, actions to
suppress interference may have to be taken.
3)
U
is also designated in other technical documentation as V
EL/SEN
Tab. A/1:
General characteristics (Part 1)
Festo P.BE-CTEU-DN-OP+MAINT-EN en 1206NH
3)
EL/SEN
2)
1) 2)
IP65/67
With corresponding connecting cable from the
Festo range of accessories
through the use of PELV circuits
All bus signals, including V– ("CAN_GND") and
V+ ("CAN_V+"), are galvanically isolated
See declaration of conformity
www.festo.com
–5 ... +50 °C
–20 ... +70 °C
93 % at 40 °C
Intended for indoor application in typical indus-
trial atmosphere. Condensation may occur.