Error Message UDLD-3-UDLD_INTERNAL_IF_ERROR: UDLD internal error, interface [chars]
[chars].
Explanation
the second [chars] is a description of the error.
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Enter the show
tech-support user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, contact
IBM technical support and provide the representative with the gathered information. For more
information about the online tools and about contacting IBM, see the
Reports" section on page
Error Message UDLD-4-UDLD_PORT_DISABLED: UDLD disabled interface [chars], [chars]
detected.
Explanation
neighbors that were functioning only in one direction, which might potentially cause spanning-tree
loops or interfere with connectivity. The cause is likely to be hardware related, either due to a bad
port, a bad cable, or a misconfigured cable. The first [chars] is the interface, and the second [chars]
is the error detected.
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Enter the show
tech-support user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, contact
IBM technical support and provide the representative with the gathered information. For more
information about the online tools and about contacting IBM, see the
Reports" section on page
Error Message UDLD-6-UDLD_PORT_RESET: UDLD reset interface [chars].
Explanation
port that was disabled by UDLD by using the udld reset privileged EXEC command or through a
hardware action such as a link-state change. [chars] is the interface.
Recommended Action
command and by copying the error message exactly as it appears on the console or system log and
entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems. For
more information about these online tools and about contacting IBM, see the
Reports" section on page
Cisco Catalyst Switch Module 3110 and 3012 for IBM BladeCenter System Message Guide
2-108
A software check failed during UDLD processing. The first [chars] is the interface, and
Copy the message exactly as it appears on the console or in the system log.
1-6.
The UDLD Protocol disabled an interface because it detected connections between
Copy the message exactly as it appears on the console or in the system log.
1-6.
The UDLD Protocol detected a unidirectional connection between neighbors. Reset the
Find out more about the error by using the show tech-support privileged EXEC
1-6.
Chapter 2
Message and Recovery Procedures
"Error Message Traceback
"Error Message Traceback
"Error Message Traceback
OL-12191-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

3112

Table of Contents