SW_VLAN Messages
Error Message SW_VLAN-4-VTP_USER_NOTIFICATION: VTP protocol user notification:
[chars].
Explanation
the situation.
Recommended Action
command and by copying the error message exactly as it appears on the console or system log and
entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems. For
more information about these online tools and about contacting IBM, see the
Reports" section on page
Error Message SW_VLAN-6-OLD_CONFIG_FILE_READ: Old version [dec] VLAN configuration
file detected and read OK. Version [dec] files will be written in the future.
Explanation
interpreted the file without a problem, but it will create files using the new format in the future. The
first [dec] is the old version number, and the second [dec] is the new version number.
Recommended Action
Error Message SW_VLAN-6-VLAN_DAT_CACHE_EXISTS: Unexpected vlan.dat cache exists.
Removing the cache and continuing the sync with new set.
Explanation
Recommended Action
Error Message SW_VLAN-3-VLAN_DAT_CACHE_SEQUENCE: Out of sequence vlan.dat sync
message. Expected: [dec]; received: [dec].
Explanation
messages from ACTIVE. The sequence number for each set of checkpoint messages starts with 1.
These messages are cached at the STANDBY until the end-of-set indicator is received. The
STANDBY received a checkpoint message with a sequence number that does not match the expected
sequence number. The first [dec] is the expected checkpoint message sequence number, and the
second [dec] is the received checkpoint message sequence number.
Recommended Action
Research and attempt to resolve the error using the Output Interpreter. Use the Bug Toolkit to look
for similar reported problems. If you still require assistance, open a case with the TA C, or contact
your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Error Message SW_VLAN-6-VTP_DOMAIN_NAME_CHG: VTP domain name changed to [chars].
Explanation
configuration to the name specified in the message. [chars] is the changed domain name.
Recommended Action
Cisco Catalyst Switch Module 3110 and 3012 for IBM BladeCenter System Message Guide
2-104
The VTP code encountered an unusual diagnostic situation. [chars] is a description of
Find out more about the error by using the show tech-support privileged EXEC
1-6.
The VLAN software detected an old version of the VLAN configuration file format. It
No action is required.
This message rarely appears and does not affect switch functionality.
No action is required.
The vlan.dat file is synchronized to the STANDBY through one or more checkpoint
Copy the message exactly as it appears on the console or in the system log.
The VLAN Trunking Protocol (VTP) domain name was changed through the
No action is required.