Cisco 3110 Message Manual page 118

Catalyst switch module for ibm bladecenter system
Hide thumbs Also See for 3110:
Table of Contents

Advertisement

SW_VLAN Messages
Error Message SW_VLAN-4-STARTUP_EXT_VLAN_CONFIG_FILE_FAILED: Failed to configure
extended range VLAN from startup-config. Error [chars].
Explanation
startup configuration file. All extended-range VLAN configurations are lost after the system boots
up. [chars] is a description of the error code.
Recommended Action
Error Message SW_VLAN-4-VLAN_CREATE_FAIL: Failed to create VLANs [chars]: [chars].
Explanation
the VLAN creation requests because the VLANs already exist as internal VLANs. The first [chars]
is the VLAN ID, and the second [chars] describes the error.
Recommended Action
EXEC command, reconfigure the feature that is using the internal VLANs, and try to create the
VLANs again. If this message appears again, copy the message exactly as it appears on the console
or in the system log. Research and attempt to resolve the error by using the Output Interpreter. Enter
the show tech-support user EXEC command to gather data that might help identify the nature of
the error. Use the Bug Toolkit to look for similar reported problems. If you still require assistance,
contact IBM technical support and provide the representative with the gathered information. For
more information about the online tools and about contacting IBM, see the
Traceback Reports" section on page
Error Message SW_VLAN-4-VTP_INTERNAL_ERROR: VLAN manager received an internal error
[dec] from vtp function [chars] [chars].
Explanation
software. [dec] is the error code, the first [chars] is the VTP function, and the second [chars] is the
error-code description.
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Enter the show
tech-support user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems.If you still require assistance, contact IBM
technical support and provide the representative with the gathered information. For more
information about the online tools and about contacting IBM, see the
Reports" section on page
Cisco Catalyst Switch Module 3110 and 3012 for IBM BladeCenter System Message Guide
2-102
The VLAN software failed to use an extended-range VLAN configuration from the
No action is required.
The specified VLANs could not be created. The port manager might not have completed
Check the internal VLAN usage by using show vlan internal usage privileged
1-6.
The VLAN manager received an unexpected error code from the VTP configuration
Copy the message exactly as it appears on the console or in the system log.
1-6.
Chapter 2
Message and Recovery Procedures
"Error Message
"Error Message Traceback
OL-12191-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

3112

Table of Contents