Pulse Measurements Mode – Option 330
Pulse Measurement Settings
How to enable Auto Analysis
— Press Mkr ->/Tools.
— Then
— Then choose from the following:
Pulse Top
Pulse Top is NOT the same as the pulse Peak. Pulse Top is used to set and
report the reference power level. You enter a value in percent, and the Pulse
Top value is reported in the Auto Analysis table in dB down from 100% of the
reference power level.
How to set Pulse Top
— Press Mkr ->/Tools
— Then
— Then enter a percent value between 0 and 100 using the numeric keypad,
Grid
Enables and disables the display of a 10 x 10 grid on the FieldFox screen.
How to enable Grid display
— Press Mkr ->/Tools
— Then
Trace Memory
A memory trace is a pulse measurement Tr 1 data trace (NOT the trace in the
Zoom window) that has been stored in the FieldFox volatile memory. It then
becomes static, meaning it is not updated with normal pulse measurements. It
can be displayed on the screen by itself, or with a pulse trace for comparison
purposes.
330
Auto Analysis
—
OFF
Analysis OFF
—
ON
The Analysis values appear below trace 1.
Pulse Top
the
arrows, or the rotary knob.
— When set to 10%, 10 dB down from the 100% acquisition is reported.
— When set to 50%, 3 dB down from the 100% acquisition is reported.
— When set to 90%, 0.5 dB down from the 100% acquisition is reported.
Grid
—
OFF
Grid OFF
—
ON
A grid of X/Y lines appears on the screen.
Keysight N9927-90001 User's Guide