System Configuration

- Ethernet Control Port Configuration

Ethernet Control Port Configuration
There are two Ethernet control ports for each BNP: one for basic management and access to the
Element Manager. On the BNP 3xr, the other port is used for DVB-CA connectivity and access.
Use the Ethernet Control Port tab screen
control ports.
From the Element Manager tabs, select Configuration -> Ethernet Control Port.
Menu Path
1. At the Ethernet Control Port tab screen, enter and/or type Ethernet control port values. Use the
following guidelines for IP addressing of these ports:
The IP address for Ethernet port 1 must be on a different subnet from any of the Gigabit
-
Ethernet IP addresses.
The IP address for Ethernet port 2 must be on a different subnet from the IP address of
-
Ethernet port 1, and any of the Gigabit Ethernet IP addresses.
2. Click Apply Configuration to save and load the settings.
You can view the current Ethernet control port configuration either at Ethernet Control Port tab
screen, or at the Chassis tab screen.
Figure 19.
Ethernet Control Port configuration
Selenio
TM
BNP User Guide, Release 3.7.1
(Figure 19
and
Table
18) to view and configure BNP Ethernet
43