- Configuring the Time Offset Table (TOT)

3. After you click the Log in button, the BNP will timeout and
display the BNP unreachable message. Click OK to dismiss
this message.
The BNP Log In screen is now displayed, with fields in which
to enter the SNMP Community String Read and Write
strings.
Enter the new Read and/or Write community strings to match the entries you changed in
above.
4. Click the Log in button.
The BNP will log you in as normal.
Note:
You will need to log in as described above for any workstation that is accessing the Element
Manager for the first time after the SNMP Read / Write Community Strings have been
changed.
Configuring the Time Offset Table (TOT)
The TOT conveys additional information about summer and winter time periods and gives the local
time offset with respect to UTC for different countries or regions. If the TOT is locally generated, user
interaction is required to define the country or region in which the receiver is operated. The BNP
supports the required DVB tables, including TOT.
Use the Set up Time Offset table (TOT) dialog for this configuration.
From the Element Manager, select Maintenance (Alt m)--> Setup Time Offset table
Menu Path
(TOT) (Alt t)
Selenio
TM
BNP User Guide, Release 3.7.1
(Figure 139
and
Table
90).