Monitoring Alarms and Events
Input GigE not operational
Cooling system failure
Failure of ad insertion/splicing
Postblack duration from ad server ignored or greater than four seconds
The four severity levels include info, minor, major, and critical.

The Status Bar

The status bar is visible regardless of the tab selected. This ensures that you can see if there are any
critical alarms that need attention. The bottom portion of the window displays the IP address to which
the BNP Element Manager is connected and the highest-priority current alert. The information is color-
coded. A green IP address section indicates that the connection is active.
For alarms, the color-coding is one of the following:
Green indicates that the alert or event displayed is informational.
Yellow indicates a situation that might need operator action.
Pink
indicates a major alarm requiring operator attention.
Red indicates a critical error has occurred and immediate operator intervention is needed.
Figure 194. The status bar