Naming, Viewing, Deleting And Editing Nit Configuration Files; Naming A Configuration File - Imagine communications Selenio BNP 2xr User Manual

Selenio broadcast network processor series
Table of Contents

Advertisement

Editing the DVB NIT Table
Table 102.
Values Supported (Continued)
NIT Section
Terrestrial Delivery
System
Array of Private Data
Array of Frequency
List
Naming, Viewing, Deleting and Editing NIT
Configuration Files

Naming a Configuration File

An opening window with no files named is shown in
present.
Selenio
TM
BNP User Guide, Release 3.7.1

- Naming, Viewing, Deleting and Editing NIT Configuration Files

Value Name
centre_frequency
bandwidth
constellation
*hierarchy_information
code_rate-HP_stream
code_rate-LP_stream
*guard_interval
transmission_mode
*other_frequency_flag
data
coding_type
Center_Frequency
Default
Range
739000000
32 bit integer (expressed in multiple of
10Hz)
0
0 (8 MHZ), 1 (7 MHZ) or 2 (6 MHZ) (3
bit field)
2
0 (QPSK), 1 (16 QAM), 2 (64 QAM) (2
bit field)
0
0 (non hierarchical),1 (alpha = 1), 2
(alpha = 2), 3 (alpha=4) (3 bit field)
0
0 (1/2),1 (2/3), 2 (3/4), 3 (5/6), 4 (7/8)
(3 bit field)
0
0 (1/2), 1 (2/3), 2 (3/4), 3 (5/6), 4 (7/8)
(3 bit field)
3
0 (1/32), 1 (1/16), 2 (1/8) or 3 (1/4) (2
bit field)
1
0 (2k mode) or 1 (8k mode) (2 bit field)
1
0 (no other frequency in use) or 1
(more than one frequency in use)
1
32 bit unsigned integer (currently
defined values are) 1 (SES), 2
(BSKYB1), 3 (BSKY2), 4 (BSKY3) BE
(BetaTechnik), 0x6000 (News
DataCom), 0x6001 (NDC1), 0x6002
(NDC2), 0x6003 (NDC3) 0x6004
(NDC4), 0x6005 (NDC5), 0x6006
(NDC6) 0x362275 (Irdeto) 0x4E544C
(NTL) 0x532D41 (SFA) 0x44414E59
(NEWS DATACOM), 0x46524549
(NEWS DATACOM) 0x53415053
(SFA)
2
0 (not defined),1 (Satellite),2 (cable)
and 3 (terrestrial)
1300000
Figure
195. The default configuration file is
257