Dvb-Ca Best Practices And Considerations - Imagine communications Selenio BNP 2xr User Manual

Selenio broadcast network processor series
Table of Contents

Advertisement

DVB Conditional Access

DVB-CA Best Practices and Considerations

The following guidelines should be taken into consideration when setting up a DVB-CA system:
In a BNP redundancy configuration only the primary BNP is connected to the EIS, ECMG, and
EMMG servers.
During switchover the old primary (now standby) disconnects to CA servers and the new primary
reconnects to them.
The Update Timer is used to avoid sending clear streams during boot up & switchover because the
boot up time and CAS reconnection time vary from configuration to configuration.
It is recommended that Ethernet Port 2 be connected downstream of an IP switch such that
multicast traffic does not spill onto the CAS network and flood the EMM and ECM traffic.
The BNP can optionally be configured to receive EMM traffic via a multicast socket on Ethernet
Port 2.
Virtual IP configuration for Ethernet Port 2 must be configured when using 1:1 chassis redundancy;
this virtual IP address must be used by CA servers (external EIS and ECMG configuration).
Selenio
TM
BNP User Guide, Release 3.7.1
- DVB-CA Best Practices and Considerations