Configuring Gige Or Asi Port(S) For Dvb-Ca System - Imagine communications Selenio BNP 2xr User Manual

Selenio broadcast network processor series
Table of Contents

Advertisement

DVB Conditional Access
Note:
If you have configured the BNP in a 1:1 redundancy environment, the Gateway IP Address for
Ethernet Port 2 must be configured.
2. Click the Apply Configuration button to indicate confirmation of the settings displayed on the
screen.
Before using the settings, the BNP will prompt for a reboot. Additional information for performing
BNP reboots is provided in "Rebooting the System" on page 196.
Settings will take effect upon completion of the reboot.

Configuring GigE or ASI Port(s) for DVB-CA System

Use guidelines in this section to set port addresses, mirroring, and/or negotiation, as described in the
following topics:
"GigE Port Input and Output Interface Configuration," next.
"ASI Port Input and Output Configuration" on page 212.
GigE Port Input and Output Interface Configuration
Use the GigE Ports tab page to manage the GigE ports for the BNP. Note that GigE port can be used
for simultaneous input and output.
Access via BNP Element Manager Configuration tab -> GigE Ports tab page.
Menu Path
Figure 149. Configure GigE - DVB-CA
1. Type the IP Address, Subnet Mask, Gateway, and Auto-negotiation information for the input
and output GigE port(s) that are to be used for encryption.
2. Click Apply Configuration to save changes.
Selenio
TM
BNP User Guide, Release 3.7.1
- DVB-CA Configuration
211