Program Redundancy - Imagine communications Selenio BNP 2xr User Manual

Selenio broadcast network processor series
Table of Contents

Advertisement

Grooming and PSIP
- Grooming - Mapping
To schedule grooming at a specific time for a one-time occurrence, perform steps 1 through 4 in the
last section,
"Creating Programs Manually"
window. Then proceed as follows:
1. From the Configure Program Mapping window,
un-check Now or Start time and click on the
pull-down menu to access the calendar/clock
screen.
2. If you want to start grooming immediately, click
OK. If you want to start at a later time, set the
time and date and then click OK.
3. To set the stop time, un-check Never or Stop
Time. The grooming schedule of
appears. If you don't want to stop grooming, click
OK. To set a stop time, set the time and date for
grooming to stop and click OK.
4. Click
to apply the mapping to the program.
OK

Program Redundancy

The BNP supports program level redundancy on all the output services. Program level standby is
configurable using the BNP Element Manager, which allows you to designate any input service as a
"standby program" with the exception of the same service. This redundancy can be configured on
output streams associated with GigE port as well as ASI ports.
The health of the standby program will be checked before failover and the BNP will not perform the
switch if the standby is degraded. In automatic recovery mode, the BNP returns back to the primary
program from the standby program when the primary program recovers from the interruption.
A program in an input TS that has SSM redundancy configured cannot be used as a backup program
for program redundancy.
Selenio