Grooming and PSIP
- Working with PIDs

Adding an Unreferenced PID as an Elementary Stream

You can add an unreferenced PID to an input transport stream. This allows you to manage
unreferenced PID inputs for various applications in the BNP output. Unreferenced PID streams are
those MPEG-2 elementary streams encapsulated in the MPEG-2 SPTS or MPTS, whose PIDs are not
referenced in any PSI (PAT and PMT) tables. These unreferenced PID streams may be purposely inserted
for some special control and applications; they could also result from the stream originator's error.
Unreferenced PIDs can come from the program inputs from GigE interfaces or from ASI inputs. In some
applications, these unreferenced PIDs need to be routed to the appropriate output GigE ports or ASI
ports as pass-through, or with-or-without the PIDs being remapped. In other cases, these unreferenced
PIDs need to be dropped, either because such unreferenced PIDs are not required or the streams are
corrupted.
Use the Create Ghost Program function to add an unreferenced PID as an ES.
From the Inputs panel of the Grooming -> Mapping tab screen, right-click on a
Menu Path
transport stream and select Create Ghost Program from the popup-menu
Figure 109. Creating an Input Ghost Program
1. Enter the Ghost Program Name.
2. Click OK. A new program stream is now displayed in
the Inputs column for the TS.
3. Right click the new Ghost Program you have created,
and choose Add Elementary Stream
present the Add Elementary Stream dialog (for single
or multiple ES).
Figure 110. Adding an Elementary Stream
Selenio
TM
BNP User Guide, Release 3.7.1
(Figure
110) to
(Figure
109).