Download Print this page

Imagine communications Selenio BNP 2xr+ Quick Start

Broadcast network processor
Hide thumbs Also See for Selenio BNP 2xr+:

Advertisement

Quick Links

1
Prepare
Supplies listed in the following table are required for this installation.
Provided in your shipping carton
BNP chassis with installed
modules.
AC power cord, for AC system, or
DC connector cables, for DC
system.
Front and rear rack-mount
brackets.
One M4 grounding nut.
2
Rackmount the BNP 2xr+
1.
Use the rack-mount screws to attach the front rack-mount
bracket to one side of the chassis. Repeat on the other side of
the chassis.
2.
Secure the front of the chassis to the rack.
3.
Slide the mounting brackets to the correct distance and secure
them.
4.
Seat the chassis on the rear mounting shelf.
5.
Ground the chassis.
Rear view of rack
Attach the rear mounting
shelf to the rack
The BNP 2xr+ can be used with one to four modules, depending on
your requirements. In the following illustration, the BNP 2xr+ is
populated with (max) 3 PROC3s, and 1 ASI card.
3
Recommended SFPs
Install approved SFPs according to the manufacturer's instructions.
Manufacturer
Part Number
Finisar
FTLF1519P1BCL
Finisar
FCMJ-8521-3
Avago
ABCU-5710RZ
Fiberdyne
FGE-SFP-T
a. These are some of the units being qualified; Imagine Communications
continues to qualify units to the specification. Please contact Imagine
Communications for an update on current SFPs.
You provide
Phillips screwdriver
Eight rack-mount screws.
Ethernet cable: for connectivity between
the BNP and the Management
workstation.
One or more GigE copper or optical SFP
modules.
Front view of rack
Description
SFP 1550nm GigE optical module
1000BaseT Copper SFP Transceiver
SFP 1550nm GigE optical module
1000BaseT Copper SFP Transceiver
Selenio™ Broadcast Network Processor
Quickstart for BNP 2xr+
4
Connect the Ports
Use the correct cable for the port type and your network
configuration:
10/100BaseT Ethernet port, used to communicate with the
management network.
ASI ports, located on the rear of the chassis. Use a push/twisting
motion to ensure proper seating of the cables.
The Gigabit Ethernet ports must have approved SFPs before
cabling.
ASI Ports
Front of BNP 2xr+
5
Power Up
1.
Connect all ports before applying power.
2.
Connect power to the chassis:
For AC power, plug one end of the AC power cable into the
BNP 2xr+ power connector. Plug the other end of the power
cable into the input power source. The unit should now have
power.
For DC power, cut the DC onnector cables to the correct
length to reach the BNP 2xr+ from the power source, and
attach the connector cables from the power source to the
BNP 2xr+ power connectors. Attach the other end of the
power connector cables into the input power source. Toggle
the external circuit breaker to the ON position. The unit
should now have power.
3.
Verify power: at the BNP 2xr+, check to ensure that the Cfg/Pwr
LED is solid green.
Note: If it is necessary to swap out the power supply, you must first
power down the BNP 2xr+, allow the fans to stop spinning, then
replace the power supply.
a
Rear of BNP 2xr+
Eight GigE Ports
10/100 Ethernet Mgmt Ports

Advertisement

loading

Summary of Contents for Imagine communications Selenio BNP 2xr+

  • Page 1 ABCU-5710RZ SFP 1550nm GigE optical module Fiberdyne FGE-SFP-T 1000BaseT Copper SFP Transceiver a. These are some of the units being qualified; Imagine Communications continues to qualify units to the specification. Please contact Imagine Communications for an update on current SFPs.
  • Page 2 Guide. • For each applicable GigE port: enable and set the IP address, subnet, and gateway, then click Apply Configuration. Go to Configuration > ASI Ports Imagine Communications, Inc. www.ImagineCommunications.com Copyright 2005-2016 Imagine Communications, Inc. All Rights Reserved 250-0376-01 Rev A Quickstart Guide BNP 2xr+, printed 2/20/16 •...