Daikin MD5 Operation Manual page 89

Variable frequency drive controller
Table of Contents

Advertisement

Table 63: Parameter Settings
MD5 Parameters
#
Name
9802
COMM PROT SEL
9901
LANGUAGE
9902
APPLIC MARCO
9905
MOTOR NOM VOLT
9906
MOTOR NOM CURR
9907
MOTOR NOM FREQ
9908
MOTOR NOM SPEED
9909
MOTOR NOM POWER
1001
EXT1 COMMANDS
1102
EXT1/EXT2 SEL
1103
REF1 SELECT
1104
REF1 MIN
1105
REF1 MAX
1106
REF2 SELECT
1201
CONST SPEED SEL
1601
RUN ENABLE
1604
FAULT RESET SEL
1607
PARAM SAVE
1608
START ENABLE 1
1611
PARAMETER VIEW
2101
START FUNCTION
2202
ACCELER TIME 1
2203
DECELER TIME 1
2605
U/F RATIO
3003
EXTERNAL FAULT 1
3009
BREAK POINT FREQ
3101
NUMBER TRIALS
3103
DELAY TIME
3104
AR OVERCURRENT
3404
OUTPUT1 DSP FORM
3405
OUTPUT1 UNIT
3415
SIGNAL3 PARAM
3418
OUTPUT3 DSP FORM
3421
OUTPUT3 MAX
4201
GAIN
4202
INTEGRATION TIME
5302
EFB STATION ID
5303
EFB BAUD RATE
5304
EFP PARITY
5306
EFB OK MESSAGES
5307
EFB CRC ERRORS
5308
EFB UART ERRORS
5309
EFB STATUS
8120
INTERLOCKS
1002
EXT2 COMMANDS
1301
MINIMUM AI1
1302
MAXIMUM AI1
3416
SIGNAL3MIN
3419
OUTOUT3UNIT
3420
OUTPUT3MIN
Vary depending on motor nameplate voltage and hp
These values vary depending on the application
Not important, will be HVAC default values
www .DaikinApplied .com
Unit
RoofPak & Self C
SAF, RAF & EAF
STD MODBUS
ENGLISH
HVAC DEFAULT
V
575
A
57
Hz
60
rpm
1775
hp
60
COMM
EXT1
COMM
Hz
0
Hz
60
KEYPAD
NOT SEL
COMM
COMM
DONE
COMM
DEFAULT
SCALAR FLYST
s
60
s
60
LINEAR
DI 2(INV)
Hz
45
5
s
3
ENABLE
DIRECT
%
AI 1
+0 .0
44ma
s
451
SAF=1, R/EAF=2
192
8 NONE 2
0
Usually a small number that grows slowly unless there is a MicroTech III communication problem
ON-LINE
NOT SEL
NOT SEL
%
MicroTech III limits minimum speed to 20 hz
%
MicroTech III limits maximum speed to 60 hz
0%
mA
mA
0
Maverick II
Maverick II
SAF
EAF
STD MODBUS
STD MODBUS
ENGLISH
ENGLISH
HVAC DEFAULT
HVAC DEFAULT
575
575
28
4
60
60
1775
1140
30
3
COMM
COMM
EXT1
EXT1
COMM
COMM
0
0
60
60
KEYPAD
KEYPAD
NOT SEL
NOT SEL
COMM
COMM
COMM
COMM
DONE
DONE
COMM
COMM
DEFAULT
DEFAULT
SCALAR FLYST
SCALAR FLYST
60
60
60
60
LINEAR
LINEAR
NOT SEL
NOT SEL
45
45
5
5
3
3
ENABLE
ENABLE
DIRECT
DIRECT
Hz
Hz
SPEED
SPEED
DIRECT
DIRECT
1800 rpm
1800 rpm
The Daikin software version [will grow over time]
370
468
1
2
192
192
8 NONE 2
8 NONE 2
Usually a big number that continues to grow
0
0
ON-LINE
ON-LINE
NOT SEL
NOT SEL
NOT SEL
NOT SEL
0 rpm
0 rpm
rpm
rpm
0
0
89
a
RoofPak
Maverick II & Rebel
Ener Rec Wheel
Ener Rec Wheel
STD MODBUS
STD MODBUS
ENGLISH
ENGLISH
HVAC DEFAULT
HVAC DEFAULT
575
575
2
0 .4
60
60
1775
1775
1
0 .2
COMM
COMM
EXT1
EXT1
COMM
COMM
0
0
60
60
KEYPAD
KEYPAD
NOT SEL
NOT SEL
COMM
COMM
COMM
COMM
DONE
DONE
COMM
COMM
DEFAULT
DEFAULT
SCALAR FLYST
SCALAR FLYST
60
60
60
60
LINEAR
LINEAR
NOT SEL
NOT SEL
45
45
5
5
3
3
ENABLE
ENABLE
DIRECT
DIRECT
Hz
Hz
SPEED
SPEED
DIRECT
DIRECT
1800 rpm
1800 rpm
165
284
3
3
192
192
8 NONE 2
8 NONE 2
0
0
ON-LINE
ON-LINE
NOT SEL
NOT SEL
NOT SEL
NOT SEL
0%
0 rpm
rpm
rpm
0
0
OM 1191 • MD5 VFD
PPendix

Advertisement

Table of Contents
loading

Table of Contents