Ambient Conditions; Applicable Standards; Ul Markings - Daikin MD5 Operation Manual

Variable frequency drive controller
Table of Contents

Advertisement

Ambient Conditions

The following table lists the MD5 environmental requirements .
Table 63: Ambient Environment Requirements
• 0...1000 m (0...3,300 ft)
Altitude
• 1000...2000 m (3,300...6,600 ft) if P
3,300 ft)
• Min . -15 ºC (5 ºF) – no frost allowed
• Max . (fsw = 1 or 4) 40 ºC (104 ºF); 50 ºC (122 ºF) if P
Ambient temperature
• Max . (fsw = 8) 40 ºC (104 ºF) if P
• Max . (fsw = 12) 30 ºC (86 ºF) if P
for MD5-xx-032A-6...MD5-xx- 062A-6) .
Relative humidity
< 95% (non-condensing)
• No conductive dust allowed .
• The MD5 should be installed in clean air according to enclosure classification.
Contamination Levels
• Cooling air must be clean, free from corrosive materials and free from electrically conductive dust .
(IEC 721-3-3)
• Chemical gases: Class 3C2
• Solid particles: Class 3S2

Applicable Standards

Drive compliance with the following standards is identified by the standards "marks" on the type code label.
Table 64: Applicable Standards
Mark
Compliance is valid with the following provisions:
• The motor and control cables are chosen as specified in
this manual .
• The installation rules of this manual are followed .
www .DaikinApplied .com
Installation Site
and I2 derated 1% every 100 m above 1000 m (300 ft above
n
and I2 derated to 90%
n
and I2 derated to 80%
n
and I2 derated to 65% (to 50% for 600 V, R4 frame sizes, that is
n
EN 50178 (1997)
EN 60204-1 (1997 + corrigendum Sep . 1998)
EN 60529 (1991 + corrigendum May 1993 +
amendment A1:2000)
EN 61800-3 (1996) + Amendment A11 (2000)
EN 61800-3 (1996) + Amendment A11 (2000)
UL 508C and C22 .2 No . 14
C22 .2 No . 14

UL Markings

When a UL mark is attached to the MD5 AC drive, it verifies
that the drive follows the provisions of UL 508C .
When a CSA mark is attached to the MD5 AC drive, it verifies
that the drive follows the provisions of C22 .2 No . 14 .
87
Storage and Transportation in
Storage
• No conductive dust allowed .
• Chemical gases: Class 1C2
• Solid particles: Class 1S2
Transportation
• No conductive dust allowed .
• Chemical gases: Class 2C2
• Solid particles: Class 2S2
Applicable Standards
Electronic equipment for use in power installations
Safety of machinery . Electrical equipment of
machines . Part 1:
General requirements . Provisions for compliance:
The final assembler of the machine is responsible for
installing:
• An emergency-stop device
• A supply disconnecting device
Degrees of protection provided by enclosures (IP
code)
EMC product standard including specific test methods
EMC product standard including specific test methods
UL Standard for Safety, Power Conversion
Equipment, second edition and CSA Standard for
Industrial Control Equipment
CSA Standard for Industrial Control Equipment
T
d
eChniCal
aTa
the protective package
-40...70 ºC (-40...158 ºF)
OM 1191 • MD5 VFD