Note the following information when installing the screw glands:
● Installation of screw glands in plastic enclosure (3SU180.-.AA0-0A.): The force of 3.0 or
3.5 Nm is applied by tightening and holding together the nut (A) and screw gland (B).
● Installation of screw glands in metal enclosure (3SU185.-.AA0-0A.): The force of 3.0 or
3.5 Nm is applied by screwing the screw gland (B) directly into the enclosure. The nut (A)
is not an essential requirement. You can however screw the nut on for additional
protection.