3Su14 Modules; Design Of A 3Su10 And 3Su11 Command Point - Siemens SIRIUS ACT 3SU1 System Manual

Industrial controls, command and signaling devices pushbuttons and signaling devices
Table of Contents

Advertisement

Overview
4.5 Types of 3SU1 actuating elements and signaling elements
4.5.4

3SU14 modules

The contact modules are equipped with a slow-action contact (1 NO contact or 1 NC
contact). These ensure a high contact stability even with small voltages and currents
(e.g., 5 V/1 mA).
Figure 4-3
Connection system
Devices with the following connections are available:
● Screw terminals with open terminal points, captive screws, funnel-shaped cable entries
and screwdriver guides
● Spring-loaded terminals for vibration-resistant connection
● Solder pin connection (0.8 mm × 0.8 mm solder pins)
4.5.5

Design of a 3SU10 and 3SU11 command point

A modular command point consists of the following elements:
● An actuating or signaling element in front of the front plate
● A holder for securing behind the front plate
● Up to three contact modules in a row (four in the case of 4-slot holders) and / or two
contact modules and one LED module (3-slot holders only) behind the front plate
● A maximum of 3x 2 (1-pole) contact modules can be stacked with a 3-slot holder
● A maximum of 4x 2 (1-pole) contact modules can be stacked with a 4-slot holder
● A comprehensive range of accessories for labeling
Mounting and stacking of the modules on a 3-slot holder
With SIRIUS ACT, the modules are mounted on the holder without any further accessories.
The modules can be stacked without needing to use a tool (max. 2x 1-pole modules behind
one other).
38
Example: 3SU1400-2AA10-1BA0 contact module
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 08/2018, A5E03457306020A/RS-AK/010

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents